Prepare electrical infrastructure
Caution
The power cord must be accessible.
The power cord must not be knotted, twisted, or trapped under any objects.
Ensure the power cord cannot be stood on or tripped over.
Each machine must be directly connected to a separate power outlet. Do not use extension cables or multi-distribution sockets.
EGYM machine | Power outlet type | Supply voltage | Rated current | Leakage current |
|---|---|---|---|---|
Smart Strength (excluding M9 & M20) | CEE 7/3 or CEE 7/5 | 230 V, 50 Hz | 8 A | < 3.5 mA |
M9 Leg Press / M20 Squat | CEE 7/3 or CEE 7/5 | 230 V, 50 Hz | 13 A | < 3.5 mA |
Fitness Hub / Fitness Hub seca edition | CEE 7/3 or CEE 7/5 | 100 - 240 V, 50/60 Hz | 4.5 A | < 3.5 mA |
Smart Flex | CEE 7/3 or CEE 7/5 | 85 - 264 V, 50/60 Hz | 0.7 A (230 V) | < 0.75 mA |
EGYM machine | Power outlet type | Supply voltage | Rated current | Leakage current |
|---|---|---|---|---|
Smart Strength (excluding M9 & M20) | Type K or CEE 7/5 | 230 V, 50 Hz | 8 A | < 3.5 mA |
M9 Leg Press / M20 Squat | Type K or CEE 7/5 | 230 V, 50 Hz | 13 A | < 3.5 mA |
Fitness Hub / Fitness Hub seca edition | Type K or CEE 7/5 | 100 - 240 V, 50/60 Hz | 4.5 A | < 3.5 mA |
Smart Flex | Type K or CEE 7/5 | 85 - 264 V, 50/60 Hz | 0.7 A (230 V) | < 0.75 mA |
EGYM machine | Power outlet type | Supply voltage | Rated current | Leakage current |
|---|---|---|---|---|
Smart Strength (excluding M9 & M20) | BS 1363 | 230 V, 50 Hz | 8 A | < 3.5 mA |
M9 Leg Press / M20 Squat | BS 1363 | 230 V, 50 Hz | 13 A | < 3.5 mA |
Fitness Hub / Fitness Hub seca edition | BS 1363 | 100 - 240 V, 50/60 Hz | 4.5 A | < 3.5 mA |
Smart Flex | BS 1363 | 85 - 264 V, 50/60 Hz | 0.7 A (230 V) | < 0.75 mA |
EGYM machine | Power outlet type | Supply voltage | Rated current | Leakage current |
|---|---|---|---|---|
Smart Strength (excluding M9 & M20) | Type I or AS 3112 | 230 V, 50 Hz | 8 A | < 3.5 mA |
M9 Leg Press / M20 Squat | Type I or AS 3112 | 230 V, 50 Hz | 13 A | < 3.5 mA |
Fitness Hub / Fitness Hub seca edition | Type I or AS 3112 | 100 - 240 V, 50/60 Hz | 4.5 A | < 3.5 mA |
EGYM machine | Power outlet type | Supply voltage | Rated current | Leakage current |
|---|---|---|---|---|
Smart Strength (excluding M9 & M20) | NEMA 5-15 | 110V / 120 V, 60Hz | 15 A | < 3.5 mA |
M9 Leg Press | NEMA 5-20 | 110V / 120 V, 60Hz | 20A | < 3.5 mA |
M20 Squat | NEMA 5-20 NEMA 6-20 * | 110V / 120 V, 60Hz 220V / 240 V, 60Hz * | 20A 13 A * | < 3.5 mA |
Fitness Hub / Fitness Hub seca edition | NEMA 5-15 | 100 - 240 V, 50/60 Hz | 4.5 A | < 3.5 mA |
Caution
* The M20 Squat can operate with different voltage configurations. The higher voltage configuration allows higher training weights. Before installing the machine with a high voltage outlet, check your machine’s configuration. The M20 voltage configuration may only be changed by an EGYM service technician.
Overcurrent Protection Devices (OCPDs), such as circuit breakers, protect electrical circuits from overload.
Caution
Contact a certified electrician to choose suitable OCPDs.
Use a circuit breaker with a short-time delay (magnetic trip threshold between 3 to 5 times the rated current)
Machines per OCPD: the sum of the rated currents must not exceed the nominal rating of the OCPD.
Caution
Do not use the OCPD to turn the machines on/off.
Residual Current Circuit Breakers (RCCBs) protect against leakage currents.
Note
A Type B+ RCCB is not recommended; the high frequency sensitivity can trip the circuit breaker unnecessarily.
Caution
Do not use RCCBs to switch machines on or off.
EGYM machine | RCCB type | Required sensitivity | Machines per RCCB |
|---|---|---|---|
Smart Strength (Vision & Series 3) | Type A (AC and pulsing current- sensitive) RCCB | IΔN = 30 mA | Maximum 4 Applies to all models, including M9 Leg Press and M20 Squat |
EGYM eco | Type B (DC-sensitive) CautionUsing unauthorized or incompatible RCCBs can compromise safety and increase the risk of electrical hazards. Tested and approved RCCBs:
| IΔN = 30 mA | Maximum 4 Applies to all models, including M9 Leg Press. |
Smart Flex | Type A (AC and pulsing current-sensitive) RCCB | IΔN = 30 mA | Maximum 8 |
Fitness Hub & Fitness Hub seca edition | The Fitness Hub does not require a separate RCCB. | ||
EGYM machine | RCCB type | Required sensitivity | Machines per RCCB |
|---|---|---|---|
Smart Strength (Vision & Series 3) | Type A (AC and pulsing current- sensitive) RCCB | IΔN = 30 mA | Maximum 4 Applies to all models, including M9 Leg Press and M20 Squat |
EGYM eco | Type B (DC-sensitive) CautionUsing unauthorized or incompatible RCCBs can compromise safety and increase the risk of electrical hazards. Tested and approved RCCBs:
| IΔN = 30 mA | Maximum 4 Applies to all models, including M9 Leg Press. |
Smart Flex | Type A (AC and pulsing current-sensitive) RCCB | IΔN = 30 mA | Maximum 8 |
Fitness Hub & Fitness Hub seca edition | The Fitness Hub does not require a separate RCCB. | ||
EGYM machine | RCCB type | Required sensitivity | Machines per RCCB |
|---|---|---|---|
Smart Strength (Vision & Series 3) | Type A (AC and pulsing current- sensitive) RCCB | IΔN = 30 mA | Maximum 4 Applies to all models, including M9 Leg Press and M20 Squat |
Fitness Hub & Fitness Hub seca edition | The Fitness Hub does not require a separate RCCB. | ||
EGYM machine | GFCI type | Required sensitivity | Machines per GFCI |
|---|---|---|---|
Smart Strength (Vision & Series 3) | Type A (AC and pulsing current- sensitive) | IΔN = 30 mA | Each machine requires a separate Class A GFCI (ground fault circuit interrupter) outlet or circuit breaker. |
Fitness Hub & Fitness Hub seca edition | The Fitness Hub does not require a separate GFCI. | ||