Skip to main content

Machine maintenance

Daily

Check machines and cables for physical damage.

Ensure safe operation.

Clean the machines.

Weekly

Reboot machines by switching them off overnight.

Monthly

Check for abnormal sound (any sound that exceeds a sound level pressure of 80 dB(A) measured at a 1-meter distance). If this occurs, contact EGYM Support.

Caution

Do not oil or lubricate the machines.

Caution

Repairs should only be carried out by qualified EGYM service technicians. This includes the replacement of wear parts.

Caution

Electrical components should only be replaced with original parts. EGYM cannot guarantee the safety and quality of machines if they have been modified.

Recurrent electrical testing is required in accordance with EN 50699 (DIN VDE 0701-0702) and DGUV V3, depending on the region.

When testing, wait until the machine has fully booted before switching it off again.

Caution

Do not apply cleaning agents directly to the display. Ensure the monitor is dried after cleaning. Moisture on the display will affect its function.

Caution

EGYM machines must be switched off before being cleaned.

Caution

Do not use a vacuum to clean the machine. For heavy soiling, contact EGYM Support or your distributor.

EGYM recommends cleaning the machines weekly, using the following products from DR. SCHNELL GmbH (www.dr-schnell.com) and STRAUSS (www.strauss.com). If these products are not available in your region, use a comparable product.

Clean the machine pads, rubber grips, display, and metal surfaces

  1. Turn off the machine.

  2. Fill a FOROL hand sprayer with 600 ml of cold water, and screw in the FOROL cartridge.

  3. Spray the solution onto a soft cloth.

  4. Wipe the pads, rubber grips, display, and metal surfaces.

  5. Wipe all surfaces dry with a clean cloth.

Clean plastic surfaces

  1. Turn off the machine.

  2. Spray the Plastic Cleaner #7 on a clean cloth.

  3. Wipe the plastic surfaces of the machine.

Clean visible marks or buildup on the pads

  1. Turn off the machine.

  2. Spray NOVO PEN-OFF onto a soft, dry cloth and work it into the affected area.

  3. Wipe the area with a clean, damp cloth using water only.

Clean visible marks or buildup on the textile covering

  1. Turn off the machine.

  2. Spray NOVO PEN-OFF onto a dry microfiber cloth and wipe the affected area of the textile covering.

    Caution

    To prevent damage, always use a microfiber cloth to clean the textile covering.

  3. Dry the textile covering completely with a clean cloth.

Clean the rubber feet

  1. Turn off the machine.

  2. Dilute the FLOORTOP cleaner according to the manufacturer instructions.

  3. Clean the rubber feet with the FLOORTOP solution.

  4. Wipe the rubber feet dry with a clean cloth.

EGYM does not provide validated product recommendations for all regions. Follow the guidelines to optimize the lifetime of your EGYM equipment:

Pictograms detailing disinfection guidance, with a check next to the wipes, and a cross through the spray bottle and chlorine