Machine maintenance

Daily

Check machines and cables for physical damage.

Ensure safe operation.

Clean the machines.

Weekly

Reboot machines by switching them off overnight.

Monthly

Check for abnormal sound (any sound that exceeds a sound level pressure of 80 dB(A) measured at a 1-meter distance). If this occurs, contact EGYM Support.

Caution

Do not oil or lubricate the machines.

Caution

Repairs should only be carried out by qualified EGYM service technicians. This includes the replacement of wear parts.

Caution

Electrical components should only be replaced with original parts. EGYM cannot guarantee the safety and quality of machines if they have been modified.

Recurrent electrical testing is required in accordance with EN 50699 (DIN VDE 0701-0702) and DGUV V3, depending on the region.

When testing, wait until the machine has fully booted before switching it off again.

EGYM recommends cleaning the machines daily, using the following products from DR. SCHNELL GmbH (www.dr-schnell.com). If these products are not available in your region, use a comparable product.

Caution

Do not apply cleaning agents directly to the monitor. Ensure the monitor is dried after cleaning. Moisture on the monitor will affect its function.

Caution

EGYM machines must be switched off before being cleaned.

Caution

Do not use a vacuum to clean the machine. For heavy soiling, contact EGYM Support or your distributor.

Surface

Product

Cleaning instruction

Upholstery

Metal surfaces

Display

Rubber grips

FOROL

Fill the FOROL hand sprayer with 600 ml of cold water, attach the FOROL cartridge and screw into place. Spray the product solution onto a soft cloth and wipe the surfaces.

Upholstery

NOVO PEN-OFF

For heavy soiling, spray NOVO PEN-OFF onto a dry cloth and work it into the surface of the upholstery. Wipe with a clean cloth dampened with water.

Textile covering

NOVO PEN-OFF

For heavy soiling, spray NOVO PEN-OFF onto a dry microfiber cloth (not directly onto the textile covering) and treat the surface. Finish with a clean dry cloth; the fabric must be dry after cleaning.

EGYM does not provide validated product recommendations for all regions. Follow the guidelines to optimize the lifetime of your EGYM equipment:

Pictograms detailing disinfection guidance, with a check next to the wipes, and a cross through the spray bottle and chlorine
  • Always use a cloth when cleaning the equipment using spray; never spray cleaning products directly onto the machines.

  • Do not use disinfectants containing chlorine as they cause severe corrosion.

  • Do not use highly concentrated alcohols (over 45%).

  • EGYM recommends using disinfectant wipes to prevent liquid from entering the machines.

Note

If disinfectant products leave a residue on the screen, clean with a damp cloth (use water) to remove residue and ensure proper function.