Machine maintenance
- Daily
Check machines and cables for physical damage.
Ensure safe operation.
Clean the machines.
- Weekly
Reboot machines by switching them off overnight.
- Monthly
Check for abnormal sound (any sound that exceeds a sound level pressure of 80 dB(A) measured at a 1-meter distance). If this occurs, contact EGYM Support.
Caution
Do not oil or lubricate the machines.
Caution
Repairs should only be carried out by qualified EGYM service technicians. This includes the replacement of wear parts.
Caution
Electrical components should only be replaced with original parts. EGYM cannot guarantee the safety and quality of machines if they have been modified.
Recurrent electrical testing is required in accordance with EN 50699 (DIN VDE 0701-0702) and DGUV V3, depending on the region.
When testing, wait until the machine has fully booted before switching it off again.
EGYM recommends cleaning the machines daily, using the following products from DR. SCHNELL GmbH (www.dr-schnell.com). If these products are not available in your region, use a comparable product.
Caution
Do not apply cleaning agents directly to the monitor. Ensure the monitor is dried after cleaning. Moisture on the monitor will affect its function.
Caution
EGYM machines must be switched off before being cleaned.
Caution
Do not use a vacuum to clean the machine. For heavy soiling, contact EGYM Support or your distributor.
Surface | Product | Cleaning instruction |
|---|---|---|
Upholstery Metal surfaces Display Rubber grips | FOROL | Fill the FOROL hand sprayer with 600 ml of cold water, attach the FOROL cartridge and screw into place. Spray the product solution onto a soft cloth and wipe the surfaces. |
Upholstery | NOVO PEN-OFF | For heavy soiling, spray NOVO PEN-OFF onto a dry cloth and work it into the surface of the upholstery. Wipe with a clean cloth dampened with water. |
Textile covering | NOVO PEN-OFF | For heavy soiling, spray NOVO PEN-OFF onto a dry microfiber cloth (not directly onto the textile covering) and treat the surface. Finish with a clean dry cloth; the fabric must be dry after cleaning. |
EGYM does not provide validated product recommendations for all regions. Follow the guidelines to optimize the lifetime of your EGYM equipment:
![]() |
Always use a cloth when cleaning the equipment using spray; never spray cleaning products directly onto the machines.
Do not use disinfectants containing chlorine as they cause severe corrosion.
Do not use highly concentrated alcohols (over 45%).
EGYM recommends using disinfectant wipes to prevent liquid from entering the machines.
Note
If disinfectant products leave a residue on the screen, clean with a damp cloth (use water) to remove residue and ensure proper function.